SK4-220D: (DIRECT REPLACEMENT FOR TELEMECANIQUE LA2DT0), TIANSHUI
Details
SK4-220D: TIANSHUI, 0.1 - 3 SECONDS, ON DELAY, PNEUMATIC TIMING HEAD ATTACHMENT.
ON DELAY TIMER
TIME 0.1 - 3 SECONDS
DELAY ON ENERGIZATION
Manufacturer: TIANSHUI 213
DIRECT REPLACEMENT FOR TELEMECANIQUE LA2DT0 AND /LA2D20.
GSC1 series 3 pole AC Contactors are used to remotely break or close AC circuits 50Hz/60Hz frequency. They protect circuits from overloading by attaching the proper thermal overload relay. Rated insulation voltage: up to AC690V
Rated operational voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC
Usage category: AC1, AC3, AC4 Certificate: UL, CE Standard: IEC60947-4:
Rated operation current under usage category AC-3 at AC 380V: up to 95A
Contact material: 90% Silver and 10% Ni for Rated current lower than 40A or 88% Sliver and 12% Cadmium Oxide for the others. The top can be attached with Auxiliary contact blocks or pneumatic time delay.
The side can be attached with Auxiliary contact blocks and interlocking mechanism.
Working condition and installation condition Ambient temperature: -5 to +40℃, and the average temperature in a 24 hour period can not exceed +35℃. Humidity is up to 50% at +40℃ ambient temperature, and 90% at 20℃. Site altitude: ≤2000m Pollution degree:
Installation category: The contactors shall be installed with screws or mounted on 35mm/75mm DIN rail
ON DELAY TIMER
TIME 0.1 - 3 SECONDS
DELAY ON ENERGIZATION
Manufacturer: TIANSHUI 213
DIRECT REPLACEMENT FOR TELEMECANIQUE LA2DT0 AND /LA2D20.
GSC1 series 3 pole AC Contactors are used to remotely break or close AC circuits 50Hz/60Hz frequency. They protect circuits from overloading by attaching the proper thermal overload relay. Rated insulation voltage: up to AC690V
Rated operational voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC
Usage category: AC1, AC3, AC4 Certificate: UL, CE Standard: IEC60947-4:
Rated operation current under usage category AC-3 at AC 380V: up to 95A
Contact material: 90% Silver and 10% Ni for Rated current lower than 40A or 88% Sliver and 12% Cadmium Oxide for the others. The top can be attached with Auxiliary contact blocks or pneumatic time delay.
The side can be attached with Auxiliary contact blocks and interlocking mechanism.
Working condition and installation condition Ambient temperature: -5 to +40℃, and the average temperature in a 24 hour period can not exceed +35℃. Humidity is up to 50% at +40℃ ambient temperature, and 90% at 20℃. Site altitude: ≤2000m Pollution degree:
Installation category: The contactors shall be installed with screws or mounted on 35mm/75mm DIN rail